Indiana ยท Data checked 21 Nov 2026

Water Quality and Treatment in Indianapolis, IN

Most of Indianapolis gets its water from Citizens Energy Group, through Citizens Water, public water system IN5249004. The supply draws on rivers, reservoirs and aquifers, and the mix behind any one address shapes how hard its water is. Citizens' 2025 figures show a wide spread, from hard to very hard. Below is what the utility reports, in plain terms, along with the state's well-water context.

Call +1 (844) 468-1919

Request a local quote or water test

Or call +1 (844) 468-1919. All fields except message are required.

How a request works

  1. You send the form or call +1 (844) 468-1919 with your ZIP and the service you're asking about.
  2. With your consent, up to 3 independent local water treatment professionals may call or text you about that request.
  3. They test or quote at your home. You compare and decide; consent is not a condition of purchase.

What we do and don't do

  • Water figures come from public sources, with the year, listed on each page.
  • We are not the installer. Local professionals are independent businesses.
  • We don't publish prices or post testimonials we can't verify.
  • No street office: we work by phone and online. We do not sell your information for unrelated marketing (Privacy Policy).

Indianapolis water at a glance

Utility
Citizens Energy Group (Citizens Water) (PWS ID IN5249004)[1]
Water sources
West Fork of the White River (with Morse Reservoir storage); Fall Creek (with Geist Reservoir and Citizens Reservoir storage); Eagle Creek Reservoir (T.W. Moses plant); Groundwater aquifers (six groundwater treatment plants plus supplemental wells).[2] Four surface water treatment plants: White River, White River North, Fall Creek, T.W. Moses. Groundwater plants: White River North, Geist Station, Harding Station, South Well Field, Harbour, Ford Road.
Hardness
Hard to very hard (average very hard) on the USGS scale. Hardness average 317 ppm (19 grains/gal); highest 460 ppm (27 grains/gal); range 148-460 ppm (8.7-27 grains/gal). Source: Citizens 2025 Water Quality Report / Indianapolis (IN5249004) water quality data (2025 data).[1, 2]
Private wells
USGS estimated about 1.68 million people in Indiana (about 25%) supplied their own household water in 2015.[3] Citizens operates six groundwater treatment plants drawing from aquifers, and a number of wells are used intermittently to supplement the White River, White River North and Fall Creek plants.[2] (Utility wells, not private wells.)
Household note
Citizens adds a small amount of ammonia so chlorine persists longer in the distribution system (chloramine residual avg 2.0 ppm, range 0.09-2.9, in 2025) and feeds orthophosphate for corrosion control. The utility notes groundwater usually has higher mineral content than surface water; Indianapolis hardness ranged 148-460 ppm across its supply.[1, 2]
Reported water-quality results
ParameterReported valueData yearContext
Fluorideavg 0.57 ppm, range 0.10-0.89[1]2025below MCL 4 ppm
Nitrateavg 1.1 ppm, range ND-4.0[1]2025below MCL 10 ppm
TTHM / HAA5TTHM avg 51 ppb, highest LRAA 58, range 22-70; HAA5 avg 29 ppb, highest LRAA 38, range 12-40[1]2025below MCLs 80 and 60 ppb (LRAA)
Lead / Copper (90th percentile)lead 4.7 ppb (range ND-19), 2 of 106 sites above 15 ppb action level; copper 0.097 ppm (range ND-0.38), 0 of 106 above[1]2025customer tap sampling
Atrazineavg 0.29 ppb, range ND-1.8[1]2025below MCL 3 ppb (RAA)
Sodiumavg 44 ppm, range 15-139[1]2025no MCL
PFASPFBS avg 0.73 ppt (ND-2.9); PFHxA avg 0.63 ppt (ND-2.5); 15 other PFAS not detected[1]2025treatment plant samples

Rivers, reservoirs and groundwater plants

Citizens names three surface sources. The West Fork of the White River is backed by storage in Morse Reservoir. Fall Creek is backed by Geist Reservoir and Citizens Reservoir. Eagle Creek Reservoir feeds the T.W. Moses plant. Surface water is treated at four plants: White River, White River North, Fall Creek and T.W. Moses.

Groundwater is the other half of the system. Citizens operates six groundwater treatment plants: White River North, Geist Station, Harding Station, South Well Field, Harbour and Ford Road. It also uses a number of wells intermittently to supplement the White River, White River North and Fall Creek plants. These are utility wells, part of the public supply, not private household wells.

Hardness depends on which plant serves you

For 2025, Citizens reports an average hardness of 317 ppm, or 19 grains per gallon, with a range of 148 to 460 ppm (8.7 to 27 grains per gallon). On the U.S. Geological Survey scale, the low end is hard and the average and high end are very hard, since anything above 180 mg/L counts as very hard.

The utility notes that groundwater usually carries more minerals than surface water. A home fed mostly from a groundwater plant can therefore see much harder water than one fed from a river plant. That spread is the reason we would not size a softener from the city-wide average. Some parts of the wider service area, such as Westfield and South Madison, are separate systems with their own data, so check which system appears on your bill.

Other 2025 results

Citizens' 2025 data includes these detections:

  • Disinfection byproducts: total trihalomethanes averaged 51 ppb (range 22 to 70, highest locational average 58) against a limit of 80. Haloacetic acids averaged 29 ppb (range 12 to 40, highest locational average 38) against 60.
  • Atrazine: average 0.29 ppb, range not detected to 1.8 ppb, against a limit of 3 ppb measured as a running annual average.
  • Nitrate: average 1.1 ppm, range not detected to 4.0, against 10 ppm. Fluoride: average 0.57 ppm, range 0.10 to 0.89, against 4 ppm.
  • Sodium: average 44 ppm, range 15 to 139 ppm, with no federal limit.
  • PFAS in treatment plant samples: PFBS averaged 0.73 parts per trillion (up to 2.9) and PFHxA 0.63 parts per trillion (up to 2.5); 15 other PFAS were not detected.

Customer tap sampling in 2025 put the lead 90th percentile at 4.7 ppb, with results from not detected to 19 ppb. Two of 106 sites were above the 15 ppb action level. Copper's 90th percentile was 0.097 ppm, with none of 106 sites above its action level. Lead results depend partly on a home's own plumbing.

How the water is treated in the pipes

Citizens adds a small amount of ammonia so the chlorine lasts longer in the distribution system. The result is chloramine, with a 2025 residual averaging 2.0 ppm (range 0.09 to 2.9). The utility also feeds orthophosphate for corrosion control. Both details matter if you are choosing a carbon filter.

Private wells around Indianapolis

Indiana leans on private wells more than most states. USGS estimated that about 1.68 million Indiana residents, roughly 25 percent of the population, supplied their own household water in 2015. We did not find a county-level count for the Indianapolis area. If your home outside Citizens' service runs on a well, none of the utility figures above apply to it, and a lab test is the starting point.

A note on these figures

All Indianapolis values come from Citizens Energy Group's 2025 water quality data and report. The utility's web page title still mentioned 2024 when we checked, but the data shown is for calendar year 2025. The same report includes another system table with hardness of 270 to 470 ppm, and we could not confirm which system it covers, so it is not used here. This page is flagged for a human fact-check before it is opened to search engines.

Indianapolis water: common questions

How hard is Indianapolis water?

Citizens Water reports a 2025 average of 317 ppm (19 grains per gallon), with a range of 148 to 460 ppm (8.7 to 27 grains per gallon). USGS classes the average as very hard. Your own level depends on which treatment plant supplies your address.

Why is my water harder than a friend's elsewhere in Indianapolis?

Citizens draws on both surface water and groundwater, and it notes that groundwater usually has higher mineral content. Homes served mainly from groundwater plants can see hardness toward the 460 ppm high end.

Was atrazine found in Indianapolis water?

Citizens' 2025 data lists atrazine at an average of 0.29 ppb, ranging from not detected to 1.8 ppb. The federal limit is 3 ppb as a running annual average.

Does Citizens Water use chloramine?

Yes. Citizens adds ammonia so chlorine lasts longer in the pipes; the 2025 chloramine residual averaged 2.0 ppm, ranging from 0.09 to 2.9 ppm.

Sources

  1. Citizens Energy Group - Indianapolis (IN5249004) & Morgan County (IN5255019) Water Quality Data. Retrieved 21 Nov 2026.
  2. Citizens 2025 Drinking Water Report (Indianapolis, Morgan Co., Westfield, Westfield-South Madison). Retrieved 21 Nov 2026.
  3. Dieter, C.A., and others, 2018, Estimated use of water in the United States in 2015: U.S. Geological Survey Circular 1441. Retrieved 21 Nov 2026.

Data checked: 21 Nov 2026. Figures describe the public water system named above, not your home's plumbing or a private well.

Call +1 (844) 468-1919